OptiCenter OC09 Decommissioning / Storage
85
Decommissioning / Storage
Shutdown
1. End the coating procedure
2. Switch off the control unit
The adjustments for high voltage, powder output volume and
electrode rinsing air remain stored.
If in disuse for several days
1. Switch off the plant with the main switch
2. Clean the gun and the components for powder conveying (see
therefore the corresponding user manuals)
3. Turn off the compressed air main supply
Storage conditions
Storage duration
If the physical conditions for metal parts and electronics are maintained,
the unit can be stored indefinitely. On the other hand, the installed
elastomeric components (pinch valve collars, O-ring seals, etc.) can
become brittle over time and crack when put under repeated loads.
Type of storage
For safety reasons, the product should only be stored in a vertical
position.
Space requirements
The space requirements correspond to the size of the components plus
the packaging.
The load-bearing capacity of the floor should be at least 500 kg/m².
There are no special requirements for the spacing to adjacent devices