EasyManua.ls Logo

Gema OptiCenter OC09 - Compressed Air Indicators; Optihopper

Gema OptiCenter OC09
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rev. 00 02/21
20
Product description OptiCenter OC09
Compressed air indicators
fig.
6
:
Gema default values after installation
30Q1
0.5 bar
AirMover (normal operation)
30Q3
3 bar
OptiHopper fluidizing air
33Q2
2 bar
Powder hopper fluidizing air
33Q1
2 bar
Fluid/suction unit fluidizing air
OptiHopper
The OptiHopper provides the following features:
Conditioning and fluidization of the coating powder
Extraction/removal of excess free-floating powder particles and the
fluidization air back into the powder circuit by means of ring injector
(AirMover)
Cleaning of the ring injector (AirMover) and the connected powder
hose with compressed air pulses for powder recovery
Manual emptying the residual powder
Manual cleaning supported by automated cleaning steps and fixed
built-in suction unit
Optional:
Monitoring and control of the powder level
fig.
7

Table of Contents

Related product manuals