OptiCenter OC09 Maintenance / Repairs
77
Cleaning the recovery system
1. Open the monocyclone
ATTENTION
Sieve damage
The sieve can be damaged when backwashing the transport hose.
Swing out the sieve completely during this cleaning step.
2. Slowly swing out the sieve and clean it with the air gun
3. Press the button on the monocyclone
The cleaning process is started.
4. Compressed air pulses blow through the hose from the OptiCenter
to the cyclone
The process can be manually stopped and resumed by the
operator.
5. Swing the funnel on the cyclone slowly away and, at the same time,
clean it off with the air gun
6. Clean the inside of the cyclone with the cleaning wand
7. Reconnect the sieve machine and funnel to the cyclone
8. If a new color is to be used: See chapter "Color change" on page 66.
OTHERWISE
9. To switch the OptiCenter to stand-by mode, press and hold the
key for 2 seconds.
10. Store the powder properly