OptiStar CG06 Automatic gun control unit Function description 15
Function description
Field of application
The OptiStar CG06 Automatic gun control unit is designed exclusively for
controlling the Gema powder coating guns (see also in chapter "Tech-
nical Data").
Any other use, beyond the above mentioned is considered non-
conforming. The manufacturer is not responsible for any damage result-
ing from this, the risk for this is assumed by the user alone!
For a better understanding of the relationships in powder coating, it is
recommended to read the operating instructions of other components,
thoroughly, so as to be familiar with their functions also.
OptiStar CG06 Automatic gun control unit
Typical characteristics
- The OptiStar CG06 Automatic gun control unit is used for au-
tomatic electrostatic powder coating equipment.
- The OptiStar CG06 Automatic gun control unit allows the
configuration of process parameters (air settings, high volt-
age settings), system parameters, process data, status in-
formation and the powder hose correction values. All air vol-
umes can be controlled centrally by the unit.
- The handling is simple and self-explanatory. The coating
personnel can save individual settings, based off personnel
experience, in 250 different programs.
- All settings for efficient powder coating are simple to operate
and repeatable. The control unit electronics permit the exact
amount of powder delivery and the adjusted values can be
read on the digital displays.
- Optional bus connections by CAN bus and DigitalBus allow a
simple, superordinated control.
- A shaping air option is available, in combination with a flow
control for all four air types.
- The OptiStar CG06 unit can be connected to all mains volt-
ages between 100-240VAC, 50-60 Hz, single phase.