V 09/18
OptiStar CG06 Automatic gun control unit Additional functions 43
Cleaning mode
The cleaning mode enables blowing off powder accumulations in the
powder hose with preset air pressure. This function is a two steps pro-
cess to activate.
First press and hold (approx. 3 seconds) program key T12 until a circulat-
ing luminous segment is shown in display A5. Then press the gun trigger
and powder hose cleaning will start.
The powder hose cleaning mode can be activated also by an optional
bus connection such as DigitalBus or CAN bus.
NOTE:
The injector must be disconnected from the pickup tube or powder
hopper prior to cleaning procedure!
The cleaning mode is terminated by pressing the program key T12.