EasyManua.ls Logo

Gema OptiStar CG06 - Correction Factor Diagram and RAM Reset; Correction Factor Diagram Explanation; RAM Reset Procedure

Default Icon
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
V 09/18
42 Additional functions OptiStar CG06 Automatic gun control unit
Correction factor - diagram
Correction factor - diagram
NOTE:
The hose length correction factor is chosen in such a way, that no
powder is visible if the powder portion is 0%, by increasing the val-
ue, the powder becomes visible then. This behavior depends on the
hose length and the hose diameter!
RAM reset
The RAM reset enables a restore of factory settings of the OptiStar CG06
gun control unit. All user-defined values in Program and Preset mode will
be set to factory default. The adjusted device type in system parameter
P0 remains stored in memory and an active keyboard lock will be deac-
tivated.
Execute the RAM reset by pressing the key T16 and the ON switch for 5
seconds.
NOTE:
By resetting the RAM, all user-defined values in Program and Preset
mode will be set to factory default!
Influence o
f
powder hose correction
(powder hose 11 mm x 12 m)
hose correction 1.8
hose correction 1.0
Powder setting [%]
Powder output [g/min]

Table of Contents

Related product manuals