V 09/18
48 • Options OptiStar CG06 Automatic gun control unit
Command table and value ranges
Opcode
[A0:A2]
Command
Value range
[D0:D8*]
Unit
0 Setting preset PA (powder output) 0 - 100% %
1 Setting preset GL (total air)
18 - 65 @ Pin=5.5bar (= 0-6.5m³/h)
18 - 70 @ Pin=6.0bar (= 0-7.0m³/h)
18 - 75 @ Pin=6.5bar (= 0-7.5m³/h)
dm³/h
2
Setting preset EL (electrode rinsing
air)
0 - 30 (= 0 - 3.0m³/h) dm³/h
3 Setting preset SHA (shaping air) 0 - 50 (= 0 - 5.0m³/h) dm³/h
4
Setting preset kV (high voltage limita-
tion)
0 - High voltage Off
10 - 100
kV
5
Setting preset µA (spray current limi-
tation
0 - 100 µA
6 Program change 1 - 250
6 Program "Flat parts" 251
Program
selection
6 Program "Complicated parts" 252
Program
selection
6 Program "Overcoat" 253
Program
selection
6
Cleaning mode
"Max. conveying, supplemental and
rinsing air"
254
Hose
rinsing
6
Cleaning mode
"Max. rinsing and supplementary air"
255
Hose
rinsing
7 Setting C2 (daily correction factor) 50 - 150 %
(D8 is not needed for these value ranges, must be left on 0)
Timing diagram
The following timing must be respected by the external control when
communicating by DigitalBus:
Timing diagram