OptiStar CG06 Automatic gun control unit Function description 17
Operating modes
The OptiStar CG06 Automatic gun control unit can be operated with two
operating modes. According to the selected application mode, spray volt-
age and spray current are automatically adjusted and limited.
Predefined operating mode (Preset mode)
The OptiStar CG06 Automatic gun control unit provides three predefined
application modes (flat parts, complicated parts and recoat parts already
painted one time).
In this operating mode, current (µA) and high voltage (kV) are preset,
powder and air volume can be adjusted and saved.
The remaining preset values are not changed by transition to the prede-
fined operating mode, they can be configured furthermore and will be
saved in memory.
User-defined operating mode (Program mode)
In this operating mode, 250 individually definable programs (P001-P250)
are available. These programs are automatically saved and can be re-
called again as the application requires.
The values for current, high voltage, powder output, total air, electrode
rinsing air and fluidizing air (if available) can be set as needed for a given
application.
NOTE:
The specified settings in the 250 programs and 3 application modes
are saved automatically, without confirmation, after a two second
delay and the display changes from preset values to actual values!