Internal signals are derived from input signals, which are logically linked
together:
System release
Setting the electrode rinsing air
1. Adjust the correct electrode rinsing air according to the ap-
plied nozzles (deflector plate, flat jet nozzle)
- Press key T9 (SELECT)
The second display level is switched over
- Press keys T7/T8
Here, the corresponding air volume value is entered
- If this display level is not operated for 3 seconds, the first
display level is switched over independently
NOTE:
By using flat jet nozzles, the factory default value is approx. 0.2
Nm³/h, by using round jet nozzles with air-rinsed deflector plates,
the factory default value is approx. 0.5 Nm³/h!
Setting the shaping air (optional)
Procedure:
1. Press key T9 (SELECT)
The second display level is switched over
2. Adjust the shaping air with the keys T5/T6
- If this display level is not operated for 3 seconds, the first
display level is switched over independently
Trigger (gun)
Sys (mains input)
SYS (DigitalBus)
Gun key
Release by CAN
System release
Error Lock
System Lock
System release logic
Ext. release
Gun release
Trigger
Error Lock
System Lock
System release