OptiStar CG06 Automatic gun control unit Additional functions 37
Additional functions
System parameters
The OptiStar CG06 Automatic gun control unit is configured with the sys-
tem parameters. The values will be saved in the equipment memory.
These values can be adjusted and requested manually or by remote in-
terface (CAN).
The system parameters are shown on the display A5 with additional al-
phanumeric abbreviated designations (for function and condition).
Entering the system parameters
1. To enter the system parameter mode, press and hold the key
T16 until the display changes (approx. 5 seconds)
2. The system parameter number is shown in the display A1
with a P placed in front
3. Adjust the corresponding system parameter value (device
type) with the keys T5/T6.
The value of the adjusted system parameter appears on dis-
play A3
4. The system parameter P0 must be set to A (automatic de-
vice) before access to system parameters P1-P9
Name Description Values Display
P0 Device type
0 - Fluidizing device (type F)
1 - Box device (vibrator) (type B)
2 - Agitator device (type S)
3 - Automatic device/
+ OptiSelect
4 - Manual device w. fluidization
F
B
S
A
S Fd
P1 FlowControl
0 - Without FlowControl
1 - Automatic recognition
F C 0
F C 1
P2 Input pressure
0 - P on = 5,5 bar
1 - P on = 6 bar
2 - P on = 6,5 bar
P 5.5
P 6.0
P 6.5
P3 Keyboard lock
0 - Remote operation mode,
no local operation possible
1 - Remote operation mode is
used as keyboard lock, reduced
operation is possible
2 - Gun release = SYSTEM
L 0
L 1
L 2