V 09/18
24 • Operating and display elements OptiStar CG06 Automatic gun control unit
Designation Function
L9
Remote PLC control
L13
Application mode for flat parts is activated
L14
Application mode for complicated parts is activated
L15
Application mode for recoating parts already coated is ac-
tivated
Input keys and switches
OptiStar CG06 Automatic gun control unit - input keys and switches
Designation Function
T1-T8
Input keys for preset values and system parameters
T9 (Select)
Switch between display levels
T10-T11
Program change
T12 (P)
Program selection for user-defined programs (max. 250)
T13
Application mode for flat parts (fixed values)
T14
Application mode for complicated parts with depressions
(fixed values)
T15
Application mode for overcoating parts already coated
(fixed values)
T16
Switching the gun on and off (system input must be active)
Switch to system parameter mode (press for at least 5
seconds)
S1/S2
Power switch On/Off
T1 T2
T3
T4
T5 T6
T7
T8
T9
T10 T11
T12
T14
T13 T15
T16 S1 S2