V 09/18
20 Technical Data OptiStar CG06 Automatic gun control unit
Electrical data
OptiStar CG06 Gun control unit
Mains input voltage 100-240 VAC
Operating frequency 50-60 Hz
Input power 40 VA
Nominal output voltage (to the gun) max. 12 V
Nominal output current (to the gun) max. 1 A
Protection type IP54
Ambient temperature range
0 °C - +40 °C
(+32 °F - +104 °F)
Max. operating temperature 85 °C (+185 °F)
Approvals
II (2) 3 D
PTB05 ATEX 5009
FM approvals (pending)
Pneumatical data
OptiStar CG06 Gun control unit
Compressed air connection 1/4" male quick release
Input pressures (must be set in the software)
5.5 bar
6.0 bar
6.5 bar
Max. input pressure 10 bar / 145 psi
Min. input pressure (while unit in operation) 6 bar / 87 psi
Max. water vapor content of the compressed air 1.3 g/m³
Max. oil vapor content of the compressed air 0.1 mg/m³
Dimensions
OptiStar CG06 Gun control unit
Width 248 mm
Depth 250 mm
Height 174 mm
Weight approx. 5.2 kg