38 Additional functions OptiStar CG06 Automatic gun control unit
Name Description Values Display
P4 Interface type
0 - Deactivated
1 - Automatic recognition
B C 0
B C 1
P5 CAN Baud rate
0 - 20 kBit/s
1 - 50 kBit/s
2 - 100 kBit/s
3 - 125 kBit/s
4 - 250 kBit/s
5 - 500 kBit/s
6 - 800 kBit/s
7 - 1 MBit/s
2 0
5 0
1 0 0
1 2 5
2 5 0
5 0 0
8 0 0
1 0 0 0
P6 CAN Node ID 1-127 N O D E
P7 Shaping air
0 - Deactivated
1 - Activated
S H A 0
S H A 1
P8
ERROR Digital-
Bus polarity
0: ERROR=0: error
1: ERROR=1: error
EPOL
P9
Supplementary
air offset
0: 0 Nm³/h
40: 4.0 Nm³/h
AOFS
Default values are marked by bold print.
Exiting the system parameter mode
Exit the system parameter mode with the key T16, and the actual values
display is switched over. The modified values will be saved in the equip-
ment memory.
If the equipment is switched off while in the system parameters mode,
any changes made will not be stored by the equipment memory!
Trigger counter and software request
The status information can be indicated on display A5 by pressing a combi-
nation of two different keys as shown. First press and hold key T12, and
then press either key T10 or T11 depending on requested information.
Status information Key combination
Trigger hours counter (total time in hours of gun
trigger time). Trigger counter can't be reset!
T12 with T10
Software version
T12 with T11
The status display is shown as long as a key is held.
Keyboard lock
The OptiStar CG06 Automatic Gun control unit contains a keyboard lock,
which prevents changing individual values for each parameter (kV, µA etc.)
within an application mode (Preset or Program). The following is not affect-
ed by the keyboard lock and will still operate under normal conditions:
- Program selection
- Display of preset values of the current program
- Display of the actual values
- Error acknowledgement
- Power ON/OFF

Table of Contents