Following data can be accessed by CANopen:
- All preset values (process data)
- All actual values (process data)
- All control values
- All system parameters (except Baud rate and CAN address)
- All error messages
- All special parameters such as software version, daily correc-
tion, powder output correction etc.
Hardware
The OptiStar control units are connected to the central PLC control unit
by 4 pin CAN bus cables. The last bus client is fitted with a terminal plug
with terminal resistor in order to terminate the network correctly. A maxi-
mum of up to 127 OptiStar control units can be operated in a network.
2.2 2.3 2.4
Gun Aux AuxPower INAir supply IN
2.11.1
1.5 1.4 1.3 1.2
2.2 2.3 2.4
Gun Aux AuxPower INAir supply IN
2.11.1
1.5 1.4 1.3 1.2
2.2 2.3 2.4
Gun Aux AuxPower INAir supply IN
2.11.1
1.5 1.4 1.3 1.2
OptiStar 1 OptiStar 2 OptiStar 127 (max.)
CAN bus - connections
CAN bus cable - plug assignment
Pin Signal Color
1 GND white
2 +24 VDC brown
3 CAN H green
4 CAN L yellow
CAN bus cable
PLC control unit
with CAN bus
Terminal resistor