V 09/18
OptiStar CG06 Automatic gun control unit Technical Data • 21
Air flow rates
The total air consists of conveying air and supplementary air, in relation
to the selected powder quantity (in %). Hereby, the total air volume is
maintained constant. For explanation, see the following examples with
correction factor C0=1.8 and conveying air nozzle=1.4 mm.
This table refers to an input pressure of 5.5 bar (system parameter
P2=0).
OptiStar CG06 Gun control unit
Total air
Powder
quantity
Conveying air
Supplementary
air
6.5 Nm³/h
81 % 5.4 Nm³/h 1.1 Nm³/h
40 % 3.7 Nm³/h 2.8 Nm³/h
0 % 1.8 Nm³/h 4.7 Nm³/h
5.5 Nm³/h
100 % 5.5 Nm³/h 0 Nm³/h
50 % 3.6 Nm³/h 1.9 Nm³/h
0 % 1.8 Nm³/h 3.7 Nm³/h
4.0 Nm³/h
100 % 4.0 Nm³/h 0 Nm³/h
50 % 2.8 Nm³/h 1.2 Nm³/h
0 % 1.8 Nm³/h 2.2 Nm³/h
OptiStar CG06 Gun control unit
Fluidizing air flow rate 0-5.0 Nm³/h
Electrode rinsing air flow rate 0-3.0 Nm³/h
Conveying air flow rate 0-5.4 Nm³/h
Supplementary air flow rate 0-4.5 Nm³/h
NOTE:
The total air consumption without FlowControl and shaping air
amounts to max. 10.5 Nm³/h (with a parameterized input pressure of
6.5 bar)!
The total air consumption with FlowControl and shaping air
amounts to max. 15.5 Nm³/h (with a parameterized input pressure of
6.5 bar)!