OptiStar CG06 Automatic gun control unit Troubleshooting 61
Code Description Criteria Remedy
High voltage:
H11
Gun error
No oscillation
Cable broken, oscillator or gun
defective
Replace gun cable, cascade etc.
Power supply:
H20
Overvoltage +15V supply
Power pack defective or over-
loaded
Replace the power pack, if error
is permanent
H21
Undervoltage +15V supply
Power pack defective or over-
loaded
Replace the power pack, if error
is permanent
H22
Undervoltage -15V supply
Power pack defective or over-
loaded
Replace the power pack, if error
is permanent
H23
Undervoltage +5V supply
Power pack defective or over-
loaded
Replace the power pack, if error
is permanent
EEPROM (equipment memory):
H24
EEPROM content invalid EEPROM error
Load factory settings, initialize
EEPROM (see therefore chapter
"RAM reset")
H25
Timeout during EEPROM writing EEPROM error
Load factory settings, initialize
EEPROM (see therefore chapter
"RAM reset")
H26
Values not correctly stored in
EEPROM during switching off
EEPROM error
Load factory settings, initialize
EEPROM (see therefore chapter
"RAM reset")
Parallel interface:
H30
Invalid command
The sent command is not sup-
ported
Reject data
H31
Parameter value outside the
value range
The sent parameter value is
outside the allowed value range
Reject data
H32
Overflow on data reception
A new command is received,
before the previous was pro-
cessed. Commands follow too
fast one after another
Reject data
CAN bus:
H40
Permanent CAN bus error
CAN CONTROLLER changes
into BUS OFF condition.
No power supply or cable is not
connected
H41
High error rate when transmit-
ting/receiving
CAN CONTROLLER changes
into ERROR_PASSIVE condi-
tion
H42
Overflow on data reception
The message to be received has
no more place in the receiver
buffer.
Messages are sent faster than
they can be processed
H43
Overflow on transmission
The message to be sent has no
more place in the transmission
buffer.
Messages are produced faster
than they can be sent
H44
Master failed
Node Guarding message is
missing longer than 2 seconds.
Connection to master failed