20
AUDIBLE ALARM
When Cautionary situations activate the Alarm, the ReACT Pro will emit a beeping sound as a warning. When the situation
corrected, the Alarm will cease. It will sound again if the same condition returns, or another Alarm condition occurs.
A single BEEP is emitted -
• after the unit performs a Diagnostic check upon push button activation.
• upon ascending to the No Deco Safety Stop depth of 20 FT (6 M).
One BEEP per second is emitted for 10 seconds-
• upon entry into Decompression Mode.
• when Elapsed Dive Time, Depth, and/or Dive Time Remaining reach their Alarm Set Points.
• when PO2 reaches .20 (ATA) < Alarm Set Point value and at the Set Point.
• upon Ascending above a Required Decompression Stop Depth.
• upon Descending deeper than 330 FT (99.9 M), or 399 FT (120 M) when set for Gauge Mode.
• when Ascent rate exceeds 60 FPM (18 MPM) when depth is greater than 60 FT (18 M), or 30 FPM (9 MPM) at 30 FT (9
M) or shallower. The Beeping will continue until the Ascent speed is reduced.
• when O2 Accumulation becomes equal to or greater than allowable per dive limit, or limit for a 24 hour period.
• when the Decompression obligation requires a Stop Depth greater than 60 FT (18 M).
A single long BEEP is emitted for 3 seconds -
• when above a required Decompression Stop Depth for more than 5 minutes.
• when the Decompression obligation requires a Stop Depth greater than 70 FT (21 M).
• upon being on the surface for 5 minutes after a Delayed Violation (described in the Special Situations section).