31
ReACT Pro
A
S
A
S
• Press/release the A button (< 2 sec) to accept the Hour, the Minute Set Point will flash.
• Press/release the S (right) button repeatedly (< 2 sec each time) to increase the Minute Set
Point from :00 up to :59 in increments of :01 (min); or depress/hold the S button to scroll
upward through the Set Points at a rate of 8 per second.
• Press/release the A button (< 2 sec) to accept the Time and access Set Sampling Rate.
• Depress both buttons for 2 seconds to revert to the Surface Main.
SET SAMPLING RATE
Factory set for 15 (seconds), Sampling Rate can be set to values of 15, 30, or 60 seconds.
• While viewing the Set 2 screen, press/release the A (left) button 9 times (< 2 sec each time),
the Set Sampling Rate screen appears with the Set Point flashing (Fig. 27).
• Press/release the S (right) button repeatedly (< 2 sec each time) to step through the Set
Points from 15 to 30 to 60.
• Press/release the A button (< 2 sec) to accept the Set Point and access Set Wet Activation.
• Depress both buttons for 2 seconds to revert to the Surface Main.
SET WET ACTIVATION
Factory set ON, the Wet Activation feature can also be set for OFF (disabled) to prevent inadvert-
ent activation during travel or storage. When set ON, the unit will automatically activate and en-
ter Dive Mode upon immersion in water.
• While viewing the Set 2 screen, press/release the A (left) button 10 times (< 2 sec each
time), the Set Wet Activation screen appears with the Set Point flashing (Fig. 28).
Fig. 27 - Set Sampling Rate
Fig. 28 - Set Wet Activation