53
ReACT Pro
TAT
FT
STOP
O
D
E
C
A
S
NITROXNITROX
TAT
FT
STOP
O
D
E
C
A
S
NITROXNITROX
CONDITIONAL VIOLATION (CV)
The unit will enter Conditional Violation if you ascend shallower than (Fig. 54a) the required
Deco Stop Depth displayed (Fig. 54b). One beep per second will sound.
The Up Arrow icon will disappear, and Total Ascent Time (TAT) and the Deco Stop Bar icon will
flash until you descend below the required Stop Depth.
If you descend below the required Stop Depth before 5 minutes have elapsed, operation will con-
tinue to function in Deco Dive Mode. In this case, no off gassing credit will be given, and for
each minute above the required Stop Depth 1
1
/
2
minutes of Penalty Time is added to required Stop
Time and Total Ascent Time.
The added Penalty Time will have to be served before off gassing credit begins again. Once the
Penalty Time is served and off gassing credit begins, required Stop Depths and Times will de-
crease toward zero, then the NiBG will recede into the No Deco Caution Zone and operation will
revert to No Deco.
DELAYED VIOLATION 1 (DV1)
If you remain above a required Deco Stop Depth for more than 5 minutes, operation will enter
DV1, which is a continuation of CV.
Total Ascent Time (TAT), the Deco Stop Bar, and NiBG DECO segment, will flash (Fig. 55) until
you descend below the required Stop Depth. Also, a single Long Beep will sound.
Fig. 54 - CV Main
a
b
Fig. 55 - DV1 Main