Help in case of malfunctions
10 / 900
Hydraulics
Trouble: Cause: Remedial action: Page:
Corn header cannot be lifted
Not enough hydraulic oil
Oil to refill
09/200
Lifting force too low
Additional lifting cylinder
required
09/120
Hydraulic functions of the header
don’t work
No flowing-through in the hydraulic
connections
Connections / couplers /
screwings to check
09/200
Transport protection blocks folding
process
Transport protection on 8
and/or 12-row header to
remove
09/040
Optional: Control valve does not work Control valve to check 09/200
Insufficient pressure of the hydraulic
system
Pressure to check, if allowed
to increase
Combine
manual
Locking blocks Locking and/or reversing
valve to readjust
09/240
Not enough hydraulic oil
Oil to refill
09/200
Folding header does not close on
point of separation
Foreign bodies hinder folding process Foreign bodies or corn
remainders to remove
09/240
Folding shields do not close
Locking not made Locking and/or reversing
valve to readjust
09/240
Folding shields open automatically
Control valve does not close reliably Control valve to check,
correct operation to secure
09/200
Folding process is not quick
enough
Combine is possibly fitted with a
throttle in the reel horizontal adjuster
If allowed, throttle to remove
Hydraulic pump to check