CE6000-UM-251-9370 7-10
7 ELECTRICAL ADJUSTMENTS
(10) The pen is lowered.
If you have only replaced the main board, input the adjustment values that were recorded.
Use the UP ARROW key or DOWN ARROW key to change the force setting. The number on the
LCD will increase or decrease.
Press the ENTER key after you input the recorded value for the 10 g-pen force.
The next specied pen force adjustment menu appears (Step (11)).
If you have replaced the pen block assembly, use the force gauge to measure the actual force.
The measured pen force should be within the specication range (10±2 g).
Note: The measuring point is when the bottom of blade holder left from the surface of cutting mat.
Do not keep pulling up the blade holder when measuring the pen force because the plotter
gives more down pressure.
Adjust the pen force value (D/A) until the force becomes to the 10±2 g.
Use the UP ARROW key or DOWN ARROW key to change the force setting. The number on the
LCD will increase or decrease.
Press the ENTER key after the measured pen force becomes to the 10±2 g.
The next specied pen force adjustment menu appears (Step (11)).
(11) Similarly, adjust the 40 g-pen force as like as step 10.
Press the ENTER key if the measured value is within the specication range (40±4 g).
Press the ENTER key if you have input the recorded value.
The next specied pen force appears.