CE6000-UM-251-9370 7-11
7 ELECTRICAL ADJUSTMENTS
(12) Similarly, adjust the 120 g-pen force as like as step 10.
Press the ENTER key if the measured value is within the specication range (120±10 g).
Press the ENTER key if you have input the recorded value.
The next specied pen force appears.
(13) Similarly, adjust the 305 g-pen force as like as step 10.
Press the ENTER key if the measured value is within the specication range (305±20 g).
Press the ENTER key if you have input the recorded value.
The next specied pen force appears.
(14) Similarly, adjust the 458 g-pen force as like as step 10.
Press the ENTER key if the measured value is within the specication range (458±20 g).
Press the ENTER key if you have input the recorded value.
(15) The following menu is displayed.
(16) Turn off the power when above menu is displayed.
Note: When adjusting the pen force, it is important to do it quickly. Delaying the pen force adjustment
changes the temperature of the actuator and causes articially lower readings. When this
happens the actual pen force may be higher than the specication. This is especially true for
the upper pen force adjustment.
Specication of the actual pen force
Specied pen force Actual force range
10 g 8 to 12 g
40 g 36 to 44 g
120 g 110 to 130 g
305 g 285 to 325 g
458 g 438 to 478 g
Note: The “ENCODER ERROR” is displayed when starting the pen force adjustment if the blade
holder is not set to the tool holder and the adjustment value is low at 10 g force adjustment.
Set the blade holder to the tool holder and then adjust the pen force.