EasyManua.ls Logo

GW Instek PEL-2004 - Edit Sequence

GW Instek PEL-2004
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION
151
Edit Sequence
Background
The Sequence function can be configured to create
a unique load profile to accurately simulate loads
in real time for single or multiple loads. For details
see page 74.
Each Sequence is composed of a number of points
with customizable current/resistance, slew rate
and duration times. Each sequence can be looped
an infinite amount of times. Sequences are only
applicable for CC (Static) and CR (Static) modes.
Parameters
Value 0~rating*1.02 / A
SlewRate
Load module dependent
SlewRate
Duration Time 0.0001~60,000 seconds
Panel operation
1. Choose a channel and mode.
Page 119, 122
2. Press the CHAN key, F4 (Seq.
Edit) to enter the Sequence Edit
menu.
03/02/09
10 : 30
Configure
Add
Point
Loop
Delete
Point
CC
Static
High
CH1
Previous
Menu
s_edit