±0.4% F.S.  ±0.4% F.S. 
MEASUREMENT 
VOLTAGE READBACK 
  Range  0~16V  0~80V  0~125V  0~500V 
  Resolution  0.5mV  2.5mV  4mV  16mV 
  Accuracy  ±(0.05%set + 0.05% F.S.)  ±(0.05%set + 0.05% F.S.) 
CURRENT READBACK 
  Range  0~7A  0~70A  0~1A  0~10A 
  Resolution  0.175mA  1.75mA  0.032mA  0.32mA 
  Accuracy  ±(0.1%set + 0.1% F.S.)  ±(0.1%set + 0.1% F.S.) 
PROTECTIVE 
Over Power Protection 
  Range  1.75~357W  1.75~357W 
  Resolution  1.75W  1.75W 
  Accuracy  ±(2%set + 0.25%F.S)  ±(2%set + 0.25%F.S) 
Over Current Protection 
  Range  0.875~71.4A  0.125~10.2A 
  Resolution  0.175A  0.025A 
  Accuracy  ±(2%set + 0.25%F.S)  ±(2%set + 0.25%F.S) 
Over Voltage Protection 
  Range  1~81.6V  2.5~500V 
  Resolution  0.2V  1.25V 
  Accuracy  ±(2%set + 0.25%F.S)  ±(2%set + 0.25%F.S) 
  Over 
Temperature 
Protection 
ؒ85Ԩ  ؒ85Ԩ 
Rated Power Protection: 
  Value  385W  385W 
  Accuracy  ±2%set  ±2%set  ±2%set 
GENERAL 
SHORT CIRCUIT 
  Current(CC) 
ؒ7.7/7A  ؒ77/70A  ؒ1.1/1A  ؒ11/10A 
  Voltage(CV)  0V  0V  0V  0V 
  Resistance(CR) 
ؒ1.25  ؒ0.025  ؒ50  ؒ1.25 
INPUT 
RESISTANCE 
(LOAD OFF) 
800K(Typical)  800K(Typical)