PEL-2000 Series User Manual
82
Von Voltage
Von Voltage is the voltage limit at which the load
will start to sink current. There are two operation
modes for Von Voltage: Von latched:ON and Von
latched:OFF.
Latched: ON will sink current when Von has been
tripped, and will continue to sink current even if
the voltage drops below the Von Voltage.
Von Latched: OFF will sink current when Von has
been tripped, but will stop sinking current when
the voltage drops below the Von Voltage setting.
As can be seen in the diagram below, when Von-Latch
is set to off, the load module will start to sink current
when the Von-voltage limit has been tripped. It will
stop sinking current when the output drops below the
Von voltage limit.