14 – 188 HEIDENHAIN Service Manual iTNC 530 HSCI
Adjusting Ethernet
settings on the
control
If you want to adapt the iTNC 530 HSCI to your laptop:
8 Write down the IP address and subnet mask of your laptop.
(See ”Requesting Ethernet settings of the laptop” on page 14 – 186.)
8 Enter the code number NET123.
8 Press the DEFINE NET soft key. --> The window Network Settings opens.
8 Click the Interfaces button.
8 Click the line of connector X26.
8 Click the Configure button. --> A new window opens:
8 If the IP address is fixed:
Write down the original settings of IP address and subnet mask.
8 If the IP address is procured automatically:
Click "Set the IP address manually":
8 Enter an appropriate IP address.
8 Enter the same subnet mask as that of your laptop.
8 Confirm by clicking OK in the window Configuring an interface.
8 In the window Network settings also click OK.
8 In the window Activate changes click Restart.
8 The control reboots, the new settings are active.
We recommend using the IP address of the laptop and increasing the last place by one.
Example:
Address of the laptop: 160.1.11.227
Address of the iTNC 530 HSCI: 160.1.11.228