EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Buffer battery; Exchanging the buffer battery

HEIDENHAIN iTNC 530 HSCI
654 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18 – 258 HEIDENHAIN Service Manual iTNC 530 HSCI
Exchanging the
buffer battery
of the MC 6222
To exchange the buffer battery of the MC 6222, proceed as follows:
8 As a precaution back up the non-volatile PLC markers and words in the RAM on the data medium.
--> See ”Non-volatile PLC markers and words” on page 11 – 134.
8 Back up the data. --> See ”Data backup” on page 14 – 181.
8 Switch off the machine, take precautions against restart, ensure that the equipment is free of
potential.
8 Open the console.
8 Screw off the rear cover plate.
8 Remove the cover plate.
8 Remove the old buffer battery.
8 Insert the new buffer battery.
Due to the non-symmetric shape of the battery there is only one possibility of inserting.
Battery type: Lithium battery, type CR 2450N (Renata), ID 315878-01
DANGER
Housing parts of the MC 6222 need to be removed to replace the buffer battery.
The device must not be under power; observe the safety precautions.
---> See ”Safety precautions” on page 2 – 15.
Note
Replacing the buffer battery may be easier, if you dismount the entire MC 6222 from the console.
In this event, label all cables before you disconnect them.
Attention
Take ESD-preventive measures (See ”ESD protection” on page 29 – 520) and work with great
care!

Table of Contents

Other manuals for HEIDENHAIN iTNC 530 HSCI

Related product manuals