4 – 28 HEIDENHAIN Service Manual iTNC 530 HSCI
8080 Uz UV 1xx
too high
DC-link voltage of the power supply unit
too high.
Check the machine parameter (braking the
spindle).
Check the braking resistor.
Replace the power supply unit.
See Service Manual Inverter Systems and
Motors.
8092 Pos. contr.
cyc. time error
MC is outputting erroneous cycle time for
CC position controller.
A hardware error has occurred.
Check machine parameter 7600.x.
Exchange drive control board.
8130 Motor brake
defective <axis>
Motor brake defective. Traverse the axis to a safe position before
power-off.
Check controls for motor brakes.
Exchange the motor.
See Service Manual Inverter Systems and
Motors.
8140 Error <axis>
field orientation
Field orientation impossible for mechanical
reasons.
Incorrect relation between electrical field and
mechanical motor motion.
Incorrect motor encoder signal.
Incorrect motor connection.
Mechanical brakes not released.
Check the machine parameters for number of
signal periods and distance for the number of
signal periods.
Check the machine parameter for the linear
distance of one motor revolution.
For linear motors: Check column STR of the
motor table.
Check the speed encoder connection.
Check the motor connection.
Release brakes during orientation.
See ”Speed encoders” on page 19 – 300. See ”Sequence for finding errors in the control
loop” on page 6 – 58.
See ”Speed encoders” on page 19 – 300.
See Service Manual Inverter Systems and
Motors.
8300 Motor brake
defective <axis>
Motor brake defective. Traverse the axis to a safe position before
power-off.
Check controls for motor brakes.
Exchange the motor.
See Service Manual Inverter Systems and
Motors.
8310 No current in
brake test <axis>
Motor connected incorrectly
Inverter connected incorrectly
Inverter defective
Motor defective
Check
the wiring of motor and inverter.
Check the inverter.
Check the motor.
See Service Manual Inverter Systems and
Motors.
8610 I2T value is
too high <axis>
Excessive load over the time of the drive. Reduce the load or the duration.
Check the motor table, power module table,
and machine parameters.
Check whether the motor and power module
are designed for the load.
See Service Manual Inverter Systems and
Motors.
Error message Possible cause of error Measures for error diagnosis and/or
corrective action
Additional information and descriptions
in the manual
Additional information and descriptions
in the manual

Table of Contents