4 – 30 HEIDENHAIN Service Manual iTNC 530 HSCI
8870 Input
frequency from
position encoder
<axis>
Noise on position encoder signals Check the encoder signals.
Check the shielding.
See ”Further examination of position and
speed encoders” on page 19 – 314.
88C0 Max.
nominal motor
speed %s
exceeded
Axis: Maximum feed rate is greater than the
maximum motor speed (N-MAX) multiplied by
MP1054.
Spindle: Maximum spindle speed is greater
than the maximum motor speed (N-MAX)
multiplied by the gear transmission ratio.
The relationship between the line count of the
position encoder and that of the motor encoder
is faulty.
The N-MAX entry in the motor table is faulty.
Incorrect entry in MP2200
EcoDyn: The selected feed rate exceeds the
max. permissible voltage.
Check the N-MAX entry in the motor table.
Check MP1010 and MP1054.
Check the machine parameters for spindle
speed.
Check the STR column in the motor table and
MP3142.
Check MP2200.x.
8A00 No inverter
enabling %.2s
Power-on of the drive not possible due to
missing enabling of the inverter via –SH1.
Check the wiring.
See ”Readiness of the inverter system” on
page 17 – 233.
See Service Manual Inverter Systems and
Motors.
8A10 AC fail %.2s Power-on of the drive not possible, because an
AC-fail signal (power supply) is active.
Test the power supply.
Check the wiring of the power supply.
See Service Manual Inverter Systems and
Motors.
8A20 Powerfail
%.2s
Power-on of the drive not possible, because a
powerfail signal (power supply) is active.
Test the power supply.
Check the wiring of the power supply.
See Service Manual Inverter Systems and
Motors.
8A40 Enabling of
axis group %.2s
Power-on of the drive not possible due to
missing drive enabling for axis groups (X150/
X151).
Check the connector on X150/X151 for correct
fit.
Check the wiring of X150/X151.
Check MP2040.x.
See ”Axis-specific drive enable via axis groups”
on page 17 – 232.
8A50 Inverter not
ready %.2s
Po
wer-on of the drive not possible, because an
inverter is not ready (RDY signal).
Check the Ready LED of the inverter.
Check the wiring of the inverter.
On interface PCBs for Siemens inverters, the
second axis is not enabled.
See ”Readiness of the inverter system” on
page 17 – 233.
See Service Manual Inverter Systems and
Motors.
8AF0 Encoder
<axis> defective
Contamination of the position encoder
Encoder cabling defective
Motor control board defective
Exchange the position encoder.
Check the encoder cable.
Exchange the motor drive-control board.
See ”Position encoders” on page 19 – 277. See ”Position encoders” on page 19 – 277.
Error message Possible cause of error Measures for error diagnosis and/or
corrective action
Additional information and descriptions
in the manual
Additional information and descriptions
in the manual