Press the EMERGENCY
STOP button and invert
either MP1040.x (algebraic
sign of the nominal speed
value) or MP210.x
(counting direction of the
position encoder signals).
Are messages
displayed such as
Incorrect entry in MP1040.x or
Movement monitoring, Standstill
monitoring,
etc.?
Switch on the main switch of machine.
Do not acknowledge the Power interrupted message
but call the MP list.
Enter the value from MP1054.x (linear distance of one
motor revolution) into MP331.x (distance for the
number of signal periods from MP332.).
Enter the line count of the motor encoder (can be obtained,
e.g., from the motor table) in MP332.x (number of signal
periods for the distance in MP331).
Activate the position encoder for the axis concerned:
Enter the value 0 for this axis in MP110.x
(assignment of the position encoder inputs).
Now you can traverse carefully
with indirect position measurement.
Yes
No
Deactivate reference mark traverse for the axis concerned:
Enter the value 0 in MP1340.x (axis sequence when
traversing the reference marks).
Exit the MP list and switch on the machine tool.
Move the axis carefully!
Position measurement via motor encoder (indirect position
measurement) of an individual axis
The machine is switched off.
Press the EMERGENCY STOP button and
turn the feed rate potentiometer to zero.