4 – 34 HEIDENHAIN Service Manual iTNC 530 HSCI
8BE0 Encoder
defective <axis>
Incorrect nominal distance between two
reference marks
Check the entry in the motor table and
MP2206.x.
Check the entry in MP334.x.
Check if the reference signal is disturbed.
See ”Encoder interface” on page 19 – 277.
8BF0 Input
frequency from
speed encoder
<axis>
Noise on speed encoder signals Check the encoder signals.
Check the shielding.
See ”Further examination of position and
speed encoders” on page 19 – 314.
8C00 Input
frequency from
position encoder
<axis>
Noise on position encoder signals Check the encoder signals.
Check the shielding.
See ”Further examination of position and
speed encoders” on page 19 – 314.
8C10 Motor
encoder <axis>
defective
No encoder signal available
Interruption in motor encoder cable
Signal amplitude of motor encoder is missing
or too small.
Check connection of motor encoder.
Check the motor encoder.
Check the amplitude of the encoder signal.
See ”Speed encoders” on page 19 – 300.
See Service Manual Inverter Systems and
Motors.
A080 CC%d
operating state
not equal MC
The automatic SRG, SBH, and SH operating
states of the MC and CC are compared
cyclically. If the values remain unequal for
longer than 500 ms, a Stop 1 is released.
Press CE to acknowledge the error message.
Switch on the machine.
Check the software version.
AC00 CC
amplitude too high
%.2s
The amplitude of the encoder signal is too high
or the contamination signal active.
Noise on motor encoder signal
Short circuit in motor encoder cable.
Motor encoder signal amplitude too high
Check connection of motor encoder (ground
connection).
Check the motor encoder.
Noise on signal
Scanning head too close to scale
For very old encoders: Incandescent lamp too
bright (spiral-wound filament short-circuited)
Adjust the scanning head.
See ”Encoder
interface” on page 19 – 277.
AC10 Motor
encoder <axis>
defective
No encoder signal available
Interruption in motor encoder cable
Signal amplitude of motor encoder is missing or
too small.
Check connection of motor encoder.
Check the motor encoder.
Check the amplitude of the encoder signal.
See ”Encoder interface” on page 19 – 277.
AC20 CC
frequency too
high %.2s
The maximum input frequency was exceeded
at an encoder input.
Noise on motor encoder signal
Check connection of motor encoder (ground
connection).
Check the motor encoder.
Check encoder signal input frequency.
See ”Speed encoders” on page 19 – 300.