February 2012 4 – 35
AC40 CC ampl.
too low %.2s
(position)
The position encoder signal amplitude is too
small or the contamination signal is active.
Interruption in encoder cable
Encoder signal amplitude missing
Check connection of encoder.
Check the encoder.
Check the amplitude of the encoder signal.
Inform your service agency.
See ”Position encoders” on page 19 – 277.
AC50 CC freq. too
high %.2s
(position)
The maximum input frequency was exceeded
at a position encoder input.
Noise on encoder signal
Check connection of encoder (ground
connection).
Check the encoder.
Check the input frequency of the encoder
signal.
See ”Further examination of position and
speed encoders” on page 19 – 314.
B900 CC%d
supply voltage %d
The Vcc supply voltage (x) was out of range.
+4 = Undervoltage Vcc (+5 V)
Excessive load from external components (e.g.
encoders).
+6 = Overvoltage Vcc (+5 V)
The power supply unit is defective.
+14 = Undervoltage Vcc (+15 V)
The power supply unit is defective.
+16 = Undervoltage Vcc (+15 V)
The power supply unit is defective.
-14 = Overvoltage Vcc (-15 V)
The power supply unit is defective.
-16 = Overvoltage Vcc (-15 V)
The power supply unit is defective.
Measure supply voltage Vcc (x).
Vcc (+5 V) < +4.75 V
Check encoder connections.
Vcc (+5 V) > +5.50 V
Exchange power supply unit.
Vcc (+15 V) < +14.25 V
Exchange power supply unit.
Vcc (+15 V) > +16.50 V
Exchange power supply unit.
Vcc (-15 V) < -14.25 V
Exchange power supply unit.
Vcc (-15 V) > -16.50 V
Exchange power supply unit.
See ”Power supply” on page 18 – 243.
BA00 CC%d
operating
temperature %d
The temperature inside the LE was out of the
permissible range.
(-128... 0...+127 = measured temperature [°C])
Temperature sensor on PCB is defective.
Insufficient ventilation of the electrical cabinet
(fan defective).
The ambient temperature is too high or too low.
Check the ventilation conditions.
See
”Information menu” on page 18 – 261.
See ”Temperature” on page 6 – 74.
C003 MC/CC%d
system clock
mismatch
Hardware error (quartz generator)
Software error
Exchange the drive-control board or processor
board.
Check the software version.
C004 Undefined
interrupt
Software error
Hardware error: Disturbance results in internal
interrupt.
Switch off the machine.
Switch on the machine.
Check the software version.
Check the grounding.
C005 Unknown
hardware
identifier
Software does not fit the hardware.
Hardware defective
Check the software version.
Exchange drive-control board.
C007 DC-link
voltage too low
Inverter defective
Line power interrupted
Check your line power supply.
Check the inverter.
See Service Manual Inverter Systems and
Motors.
Error message Possible cause of error Measures for error diagnosis and/or
corrective action
Additional information and descriptions
in the manual
Additional information and descriptions