21 – 336 HEIDENHAIN Service Manual iTNC 530 HSCI
Motor table 8 Open the machine parameter list.
8 Place the cursor on the motor concerned (MP2200.x).
8 Switch to the next soft-key row.
8 Press this soft key. --> The table with the motors appears:
The original table (MOTOR.MOT) contains asynchronous motors, linear motors, synchronous motors,
torque motors and special spindle motors for the volts-per-hertz control mode of various
manufacturers.
The original HEIDENHAIN motor table is stored in the SYS partition of the data medium.
The OEM can create his own motor table (with additional motors and/or edited data) which is
stored in the PLC partition of the data medium.
If the motor tables have the same name (MOTOR.MOT), the data of the OEM table in the PLC partition
have priority.
Do not change any values in the motor table! This could lead to damage to property
or persons.