EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Page 407

HEIDENHAIN iTNC 530 HSCI
654 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25 – 408 HEIDENHAIN Service Manual iTNC 530 HSCI
Activating the potentiometers on HR 520:
After selection of the handwheel mode, the potentiometers of the keyboard are still active.
To test the handwheel potentiometers, you have to activate them:
8 Pick up the handwheel.
8 Press and hold the CTRL key, then actuate the HANDWHEEL key.
--> The menu Select override: appears in the handwheel display.
8 Press the HW soft key to activate the handwheel potentiometers.
--> The information Handwheel override active appears on the control screen.
Figure: Active potentiometers on HR 520
Deactivating the potentiometers on HR 520:
If you want to deactivate the HR 520 handwheel after the tests described, first reactivate the
potentiometers of the keyboard.
Proceed as follows:
8 Pick up the handwheel.
8 Press and hold the CTRL key, then actuate the HANDWHEEL key.
--> The menu Select override: appears in the handwheel display.
8 Press the KBD (keyboard) soft key to activate the potentiometers of the keyboard.
8 Press the HANDWHEEL key.
--> The window Handwheel active on the control screen is closed, the handwheel is deselected.
Note
These PLC words can also be shown in the integrated oscilloscope.
--> See ”Checking the potentiometers” on page 23 – 376.