29 – 532 HEIDENHAIN Service Manual iTNC 530 HSCI
Accepting
hardware updates
After start-up, the control may display the window Hardware/firmware change detected.
8 Accept these changes. --> See ”Recognizing and accepting hardware updates” on page 29 – 523.
Running
firmware updates
Firmware updates may be required for the exchange MC. The NC software automatically detects,
whether this is required.
8 Run these firmware updates. --> See ”Detecting and loading firmware updates” on page 29 – 524.
Restoring non-
volatile PLC
markers and
words
8 After restarting the control you must not acknowledge the Power interrupted message.
8 Write the non-volatile PLC markers and words from the data medium to the RAM of the new control.
--> See ”Non-volatile PLC markers and words” on page 11 – 134.
Setting date and
time on the new
MC 6222
8 Check the date and time of the control and reset it, if necessary. --> See ”Setting the system time”
on page 13 – 173.
Accepting axis
positions
8 Switch on the machine.
Regarding the axis positions, the following window may be displayed:
8 Check whether the "new" positions are correct and then confirm them.
Note
Background:
The axis positions of EnDat encoders are saved to the RAM of the control when the machine is
switched off. The actual axis positions of the machine are not identical with the values in the RAM
of the exchange MC.