31 – 584 HEIDENHAIN Service Manual iTNC 530 HSCI
MP860.x Datum for synchronous control
Format: %xxx
Input: Bit 0 – Datum position for synchronous control
0: Datum at position after switch-on
1: Datum at reference marks (machine datum)
Bit 1 – Master-slave torque control
0: Axis is not slave axis in master-slave torque control
1: Axis is slave axis in master-slave torque control
Bit 2 – Brake test of slave axis
0: Test the brakes of a synchronized axis simultaneously
1: Test the brakes of a synchronized axis successively
PLC
RUN
MP910.x Positive software limit switches, traverse range 1 (default setting after power on)
Input: –99 999.9999 to +99 999.9999 [mm] or [°]
PLC
RUN
MP911.x Positive software limit switches, traverse range 2
Input: –99 999.9999 to +99 999.9999 [mm] or [°]
PLC
RUN
MP912.x Positive software limit switches, traverse range 3
Input: –99 999.9999 to +99 999.9999 [mm] or [°]
PLC
RUN
MP920.x Negative software limit switches, traverse range 1 (default setting after power on)
Input: –99 999.9999 to +99 999.9999 [mm] or [°]
PLC
RUN
MP921.x Negative software limit switches, traverse range 2
Input: –99 999.9999 to +99 999.9999 [mm] or [°]
PLC
RUN
MP922.x Negative software limit switches, traverse range 3
Input: –99 999.9999 to +99 999.9999 [mm] or [°]
PLC
RUN
MP950.x Datum for positioning blocks with M92 for axes 1 to 9
Input: –99 999.9999 to +99 999.9999 [mm] or [°]
Values with respect to the machine datum
PLC
RUN
MP951.x Simulated tool-change position for TOOL CALL during mid-program startup (block scan)
Input: –99 999.9999 to +99 999.9999 [mm] or [°]
PLC
RUN
MP960.x Machine datum
Input: –1.79769313486E+308 to
+1.79769313486E+308 [mm] or [°]
Values with respect to the scale reference point
PLC
RUN
MP Function and input Software
version and
behavior