31 – 604 HEIDENHAIN Service Manual iTNC 530 HSCI
MP3420 Spindle positioning window
Input: 0 to 360.0000 [°]
PLC
RUN
MP3430 Deviation of the reference mark from the desired position (spindle preset)
Input: 0 to 360 [°]
PLC
RUN
MP3440.0-7 k
V
factor for spindle orientation for gear ranges 1 to 8
Input: 0.1 to 10 [(1000°/ min) /°]
PLC
RUN
MP3450.0-7 Number of spindle position-encoder revolutions for gear ranges 1 to 8
Input: 0 to 65 535
0: No transmission
PLC
RUN
MP3451.0-7 Number of spindle revolutions for gear ranges 1 to 8
Input: 0 to 65 535
0: No transmission
PLC
RUN
MP3510.0-7 Rated speed for the gear ranges 1 to 8
Input: 0 to 99 999.999 [min
–1
]
PLC
RUN
MP3515.0-7 Maximum spindle speed for gear ranges 1 to 8
Input: 0 to 99 999.999 [min
–1
]
PLC
RUN
MP3520.0 Speed activation through marker M4011
Input: 0 to 99 999.999 [min
–1
]
PLC
RUN
MP3520.1 Spindle speed for oriented stop
Input: 0 to 99 999.999 [min
–1
]
MP3530 Increased spindle power for roughing
Input: 0 = Not active
1 = Increased spindle power for roughing
MP3540 Permissible spindle speed shortfall
Input: 0.001 to 0.999
0: Monitoring not active
MP3542 Minimum spindle speed as of which the monitoring in MP3540 becomes active
Input: 0.001 to 0.999
0: Monitoring not active
MP3550 Delay of emergency-stop reaction of spindles
Input: 0.001 to 0.100 [s]
0: Delay not active
MP Function and input Software
version and
behavior