Access level of Arming
The user in level 2 or 3 has the permission to arm or partly arm
the system.
Arming Indicaon
The arming/disaring indicator keeps solid blue for 5s.
Reason of Arming Failure
•
Intrusion detector triggered (excepts the detector on the exit
route).
•
Panic alarm device triggered.
•
Tampering alarm occurred.
•
Communicaon excepon
•
Mian power supply excepon
•
Backup baery excepon
•
Alarm receiving fault
•
Siren fault
•
Low
baery of the keyfob
•
Others
Arming with Fault
While the arming is stopped with fault, user in level 2 has the
permission to arm the system with fault (forced arming).
Fored arming only taks eect on the current arming operaon.
The forced arming operaon will be record in the event log.
5.2 Disarming
You can disarm the system with keypad, keyfob, card, client
soware, or mobile client.
Disarming Indicaon
The arming/disarming indicator ashes 30s while the user
successfully disarm the system through the entry/exit route.
The system will report the disarming result
aer the operaon
completed.
Entry Delay
Duraon
Ensure that mer is no longer than 45 seconds in order to comply
with EN50131-1.
Early Alarm
If either the intrusion or tampering alarm occurs on the enter/exit
route when the control panel is in the status of entry delay, the
control panel then enters the early alarm mode.
The early alarm
duraon can be set (> 30s).
The control panel will reports the alarm only if the alarm event
lasts over the duraon of early alarm with the addion of entry
delay.
54