E. Access Levels
Level Descripon
1 Access by any person; for example the general public.
2
User access by an operator; for example customers
(systems users).
3
User access by an engineer; for example an alarm
company professional.
4 User access by the manufacturer of the equipment.
Table E-1 Permission of the Access Level
Funcon
Permission
1 2 3
a
4
b
Arming No Yes Yes No
Disarming No Yes Yes No
Restoring/Clearing
Alarm
No Yes Yes No
Entering Walk Test
Mode
No Yes Yes No
Bypass(zone)/
Disabling/Force
Arming
No Yes Yes No
Adding/Changing
Vericaon Code
No Yes
d
Yes
d
Yes
d
Adding/Eding Level 2
User and Vericaon
Code
No Yes Yes No
Adding/Eding
Conguraon Data
No No Yes No
Replacing soware
and rmware
No No No Yes
Note
a
By the condion of being accredited by user in level 2.
b
By the
condion of being accredited by user in level 2 and level 3.
d
Users
can only edit their own user code.
•
The user level 2 can assign the login permission of the
controller to the user level 3 or level 4 in the
sengs page.
•
The user level 2 should assign permissions to the user level 3 if
the user level 3 wants to login the controller remotely.
71