Check dierent items to assign permissions.
Single Key Sengs
Select from the drop-down list to set I key and II key's
funcons
Combinaon Keys Sengs
Select from the drop-down list to set combinaon keys'
funcons.
4.
Click OK.
5.
Oponal: Click to edit the keyfob informaon.
6.
Oponal: Delete a single keyfob or check mulple keyfobs and
click Delete to delete the keyfobs in batch.
Add/Edit/Delete Tag (Card)
You can add tag to the security control panel and you can use the
tag(card) to arm/disarm the zone. You can also edit the tag
informaon or delete the tag from the security control panel.
Steps
1.
Click User Management → Card to enter the management
page.
2.
Click Add and place a tag(card) on the tag(card) area of the
control panel.
3.
Customize a name for the tag(card) in the pop-up window.
4.
Select the card type and tag(card) linked paron.
5.
Select the permission for the tag(card).
Note
You should allocate at least a permission for the tag(card).
6.
Click OK and the tag
informaon will be displayed in the list.
Note
The tag supports at least 20-thousand serial numbers.
7.
Oponal: Click and you can change the tag(card) name.
8.
Oponal: Delete a single tag(card) or check mulple
tags(cards) and click Delete to delete cards in batch.
4.3.6 Maintenance
Test
The security control panel supports walk test funcon.
Steps
1.
Enter Maintenance → Test → to enable the
funcon.
Note
Only when all the detectors are without fault, you can enter
the mode TEST mode.
36