A.2 Mutual Exclusion of Funcons
A.2.1 Unable to Enter Registraon Mode
Fault Descripon:
Click the panel funcon key, and prompt key invalid.
Soluon:
The panel is in "AP" mode. Switch the panel to "staon" mode,
and then try to enter the registraon mode again.
A.2.2 Unable to Enter RF Signal Query Mode
Fault Descripon:
Double-click the host funcon key, and the prompt buon invalid.
Soluon:
The panel is in "AP" mode. Soluon: switch the panel to "staon"
mode, and then try to enter the RF signal query mode again.
A.3 Zone Fault
A.3.1 Zone is Oine
Fault Descripon:
View status of zones which displays oine.
Soluon:
Check whether the detector reports undervoltage. Replace the
detector
baery
A.3.2 Zone Tamper-proof
Fault Descripon:
View status of zones which displays tamper-proof.
Soluon:
Make tamper-proof buon of the detector holden.
A.3.3 Zone Triggered/Fault
Fault Descripon:
View status of zones which displays triggered/fault.
Soluon:
Reset the detector.
A.4 Problems While Arming
A.4.1 Failure in Arming (When the Arming Process
is Not Started)
Fault Descripon:
When the panel is arming, prompt arming fails.
Soluon:
The panel does not enable "forced arming", and when there is a
fault in the zone, the arming will fail. Please turn on the "forced
arming" enable, or restore the zone to the normal status.
A.5 Operaonal Failure
A.5.1 Failed to Enter the Test Mode
Fault Descripon:
Failed to enable test mode, prompng "A fault in the zone".
Soluon:
63