Page #39 background image
Note
The buzzer beeps slowly 2 minutes before the auto arming
starts, and beeps rapidly 1 minute before the auto arming
starts.
Note
You can select to enable forced arming on the System
Opons page. While the funcon is enabled, the system will
be armed regardless of the fault.
Note
If the public paron is enabled, the paron 1 dose not
support auto arming.
Enable Auto Disarming
Enable the funcon and set the disarming start me. The
zone will be disarmed according to the congured me.
Note
The auto arming me and the auto disarming me cannot
be the same.
Note
If the public paron is enabled, the paron 1 dose not
support auto disarming.
Late to Disarm
Enable the funcon and set the me. If the alarm is
triggered aer the congured me, the person will be
considered as late.
Note
You should enable the Panel Management Nocaon
funcon in Communicaon Parameters → Event
Communicaon before enabling the Late to Disarm
funcon.
Weekend Excepon
Enable the funcon and the zone will not be armed in the
weekend.
Siren Delay Time (Perimeter Alarm)
If you have set the perimeter zone, you can set the delayed
me for the zone.
Note
The available me duraon range is from 0 s to 600 s.
Alarm Duraon
Set the me duraon of the alarm.
Note
The available me duraon range is from 1 s to 900 s.
5.
Click Save.
4.3.4 Video Management