Input Types Operaons
Fire Zone
The zone acvates all the me with
sound/siren output when alarm
occurs.
Audible Response: Trigger the
system sound and siren.
Voice Prompt: Zone X re alarm.
Gas Zone
The zone acvates all the me with
sound/siren output when alarm
occurs.
Audible Response: Trigger the
system sound and siren.
Voice Prompt: Zone X gas alarm.
Medical Zone
The zone acvates all the me with
beep conrmaon when alarm
occurs.
Audible Response: Trigger the
system sound and siren.
Voice Prompt: Zone X medical
alarm.
Timeout Zone
The zone acvates all the me. The
zone type is used to monitor and
report the "ACTIVE" status of a
zone, but it will only report and
alarm this status aer the
programmed me has expired (1 to
599) seconds.
Disabled Zone
Alarms will not be acvated when
the zone is triggered or tampered.
Audible Response: No system sound
(voice prompt or siren).
Virtual Zone
(Keypad/Keyfob)
The system will immediately alarm
when it detects triggering event
aer system armed.
Audible Response: Trigger the
system sound and siren.
Voice Prompt: Buzzer beeps.
Tamper Alarm
The system will immediately alarm
when it detects triggering event
aer system armed.
Audible Response: Trigger the
system sound and siren.
Voice Prompt: Zone X tampered.
Link
Trigger the linked device when
event occurs.
67