2.
Set the RS-485 parameters.
Note
You should keep the parameters of the device and the computer or terminal the same.
3.
Click Save.
Note
The sengs take eect only for the PTZ channel.
14.13 Set Same Unit
Set the same temperature unit and distance unit. When you enable this funcon, the unit cannot
be
congured separately in other seng pages
Steps
1.
Go to Conguraon → System → System Sengs → Unit Sengs .
2.
Check Use Same Unit.
3.
Set the temperature unit and distance unit.
4.
Click Save.
14.14 Set Visible Light Parameters
When the FOVs (Field of View) of the opcal channel and thermal channel are not the same, adjust
the visible light opcal axis to make sure the FOVs in the two channels are the same.
Steps
1.
Go to Conguraon → System → Maintenance → System Service .
2.
Select Visible Light
Opcal Axis Adjustment from the drop-down list.
3.
Check Enable Visible Light Opcal Axis Adjustment.
4.
Adjust the opcal zoom rao to the maximum value via PTZ control panel.
5.
Click the
direcon buons to adjust the posion of the visible light opcal axis.
6.
Adjust the sensivity. The higher the value is, the faster the cursor moves.
7.
Click Save when the FOVs of the
opcal channel and thermal channel are the same.
Note
●
If the FOVs of the opcal channel and thermal channel are not the same, funcons such as
reect light lter and smoke auxiliary detecon may be aected.
●
Please adjust the visible light opcal axis under professional assistance.
Thermal & Opcal Bi-spectrum PTZ Network Camera User Manual