Steps
1.
Go to Conguraon → VCA → Camera 01/Camera 02 → Basic Sengs → Polling Plan .
2.
Select a polling mode.
Auto The device automacally acvates the opcal channel for perimeter protecon in
dayme and the thermal channel at night.
Manual You can manually set the working shis for the channels.
a. Select the Polling Mode as Manual.
b. Select Opcal Channel or Thermal Channel for the drop-down list.
c. Drag to draw
me bars on the schedule. Click on the drawn bar to adjust the
me and the channel.
Note
The schedule for the channels cannot overlap.
3.
Click Save.
6.4 Advanced
Conguraon
Go to Conguraon → VCA → Advanced Conguraon and congure the parameters.
Detecon Parameters
Single Alarm
The system only sends alarm once for one target triggering. Otherwise, the alarm will be
triggered
connuously unl the target disappears.
Scene Modes
The scene mode is set to be General by default. Select Distant View when you are far from the
targets. Select Leaves Interfered View when there are shaking targets in the scene, such as
leaves.
Tracking Parameters
Post-tracking
Set the
duraon of automac tracking of the target aer it stops. E.g., set post-tracking duraon
to 10s, the camera tracks the target unl that it stop and has been sll for over 10s.
Back to Scene Time
Set the duraon of the camera moving back to original scene aer perimeter protecon is
started.
Restore Parameters
Restore Default
Click Restore to restore the parameters to the default.
Restart VCA