1.
Go to Conguraon → VCA → Camera 01/Camera 02 → Basic Sengs → Polling Plan .
2.
Select a polling mode.
Auto The device automacally acvates the opcal channel for perimeter protecon in
dayme and the thermal channel at night.
Manual You can manually set the working shis for the channels.
a. Select the Polling Mode as Manual.
b. Select Opcal Channel or Thermal Channel for the drop-down list.
c. Drag to draw
me bars on the schedule. Click on the drawn bar to adjust the
me and the channel.
Note
The schedule for the channels cannot overlap.
3.
Click Save.
6.4 Advanced
Conguraon
Go to Conguraon → VCA → Advanced Conguraon and congure the parameters.
Detecon Parameters
Single Alarm
The system only sends alarm once for one target triggering. Otherwise, the alarm will be
triggered
connuously unl the target disappears.
Scene Modes
The scene mode is set to be General by default. Select Distant View when you are far from the
targets. Select Leaves Interfered View when there are shaking targets in the scene, such as
leaves.
Tracking Parameters
Post-tracking
Set the
duraon of automac tracking of the target aer it stops. E.g., set post-tracking duraon
to 10s, the camera tracks the target unl that it stop and has been sll for over 10s.
Back to Scene Time
Set the duraon of the camera moving back to original scene aer perimeter protecon is
started.
Restore Parameters
Restore Default
Click Restore to restore the parameters to the default.