4.5 Set Fire Detecon Parameters
To avoid the potenal re damage, you should congure the re detecon funcon for certain
areas. The detail
conguraon steps show as below.
Before You Start
The re detecon funcon can locate the re source area quickly together with patrol or linear
scan. Please refer to Set Patrol Scan for conguring patrol. Please refer to Set the Presets for
presets
seng.
Please refer to Set Device Posion for locang the re source posion.
Go to
Conguraon → Local , set the re point parameters.
Locate Highest Temperature Point
Click and save to show the posion of the highest temperature on the interface.
Frame Fire Point
Click and save to frame the detected re source.
Steps
1.
Go to Conguraon → Event → Smart Event , select Fire and Smoke Detecon.
2.
Check Enable Fire and Smoke
Detecon.
3.
Refer to Detecon Mode and Applicaon Scene for seng the re detecon mode.
4.
Check Display Fire Source Frame on Stream to display a red frame around the
re source on
stream when re occurs.
5.
Seng the parameters of re detecon.
Detecon Mode
by Single Frame
It can quickly detect
re while moving, but have a high false posive rate.