5.2.1 Set a Detecon Scene
Mulple detecon scenes are supported for both channels. You can create scenes and set the
tracking parameters for
beer target monitoring performance. The sengs may vary according to
dierent camera models.
Steps
1.
Go to Conguraon → Ship Detecon .
2.
Click Scene
Conguraon and New Scene to create one or more scenes.
3.
Select a numbered scene from the navigaon bar on the le and enter a Scene Name.
Note
If you want to show the name on the image, check Display Scene Name.
4.
Select a Channel No. from the drop down list.
5.
Set the Scene Rao by controlling the zoom in/out buons.
6.
Check Track to enable the target tracking funcon for the scene.
7.
Oponal: Check Limited Tracking and set the auto tracking range.
The camera channel tracks a target only within the set auto tracking range.
1) Control the PTZ buons to a desired scene and click Set Up Limit to save the posion as the
scene's upper boundary.
2) Repeat to set the
le, right and lower boundaries of the scene.
Tracking Duraon
Set the duraon of tracking. If the value is selected as 0, the tracking duraon will not be
limited.
Zooming
Rao
It is the zoomed-in level when the camera channel is tracking a target.
Go to Conguraon → Ship Detecon → Zooming Rao , select a scene from the drop-
down list, and control the zoom in/out
buons to get a desired zooming level, and save the
sengs.
Post-tracking
Set the duraon of automac tracking of the target aer it stops.
Go to
Conguraon → VCA → Advanced Conguraon , and set parameter.
8.
Click Save.
5.2.2 Set Ship Flow
Detecon
Aer enabling this funcon, the device will trigger an alarm if ships enter or exit the set regions,
and will count the ships that pass across the alarm line for the rst me.
Steps
1.
Go to Conguraon → Ship Detecon → Scene Conguraon → Scene x → Rule .
Thermal & Opcal Bi-spectrum PTZ Network Camera User Manual