3.3 Automac Thermography
Congure the temperature measurement parameters and temperature measurement rules. The
device can measure the actual temperature and output alarms when temperature exceeds the
alarm threshold value.
3.3.1 Set Thermography Parameters
Congure the parameters of temperature measurement.
Steps
1.
Go to
Conguraon → Local , enable Display Temperature Info.
Display Temperature Info.
Select Yes to display temperature informaon on live view.
Enable Rules to display the rules informaon on live view.
2.
Click Save.
3.
Go to Conguraon → Temperature Measurement → Basic Sengs to congure parameters.
Enable Temperature Measurement
Check to enable temperature measurement
funcon.
Enable Color-Temperature
Check to display Temperature-Color Ruler in live view.
Display Temperature Info. on Stream
Check to display temperature informaon on the stream.
Display Temperature in Opcal Channel
Check to display thermal channel temperature informaon in the opcal channel.
Display Max./Min./Average Temperature
Check to display maximum/minimum/average temperature informaon on live view when
the temperature measurement rule is line or area.
Rule Name
Display the rule name rather than the rule ID on the live view. You can set the name in expert
temperature measurement mode for the rule.
Posion of Thermometry Info
Select the posion of temperature informaon showed on the live view.
Near Target: Display the
informaon beside the temperature measurement rule.
Top Le: Display the informaon on the top le of screen.
Add Original Data on Capture
Check to add data on alarm triggered capture of thermal channel.
Thermal & Opcal Bi-spectrum PTZ Network Camera User Manual