Add Original Data on Stream
Add and save original raw data to stream. The funcon requires higher network bandwidth.
Data Refresh Interval
It means the refresh interval of original data.
Display Pixel-to-Pixel Thermometry Data on Stream
Add and save real-me pixel-to-pixel thermometry data to stream. The funcon requires
higher network bandwidth.
The
funcon varies according to dierent camera models.
Pixel-to-Pixel Thermometry Data Refresh Interval
It means the refresh interval of thermometry data.
Unit
Display temperature with Degree Celsius (°C)/Degree Fahrenheit (°F)/Degree Kelvin (K).
Temperature Range
Select the temperature measurement range. The device can adjust the temperature range
automacally if you select Auto.
Atmospheric Temperature
Set the atmospheric temperature.
Atmospheric Humidity
Set the atmospheric humidity.
Atmospheric Transmissivity
Set the atmospheric transmissivity from 0 to 1.
Distance Mode
Select the distance mode for temperature measurement. Fixed Distance and
Self-Adapon
are selectable.
Version
View the version of current algorithm.
Calibraon File Version
View the version of calibraon le.
Alarm Interval
Set the alarm interval between two alarms.
Reect Light Filter
Enable these funcons if there is strong reected light from sun, or it may cause false alarm.
The lter sensivity can be adjusted.
Check Display Filtering Status, and the OSD will be displayed when the funcon is enabled.
Click Restart to restart the algorithm library of
reect light lter.
The Reect Light Filter funcon varies according to dierent camera models.
Thermal & Opcal Bi-spectrum PTZ Network Camera User Manual