EasyManua.ls Logo

HIKVISION DS-2TD6267-75C4L/WY - Set Dredger Detection

HIKVISION DS-2TD6267-75C4L/WY
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.
Select Ship Flow Detecon from the drop-down list.
3.
Check Region Entrance/Exing Alarm.
4.
Draw an area.
1) Click and drag the mouse in the live video window to draw the area. You can drag the corners
of the rectangle area to draw a polygon area.
2)
Oponal: Click Stop Drawing to nish drawing or click Clear All to clear all of the areas you set
without saving them.
3)
Click to add alarm lines. The device will count automacally when a ship passes across the
alarm line for the rst me and triggers an alarm.
4) Click and select the alarm line to adjust its length and posion. The alarm line should be
longer than the width of ship detecon area.
Note
Avoid water areas with oang objects or aquaculture.
Set mulple alarm lines in wide river to improve the detecon accuracy.
5.
Set the min. size and max. size of the target. When the target is smaller than the min. size or
bigger than the max. size, the device can detect the target, but no alarm will be triggered.
6.
Click Recount to restart the counter.
7.
Click Save.
8.
Refer to
Set Arming Schedule for seng scheduled me. Refer to Linkage Method Sengs for
seng linkage method.
5.2.3 Set Dredger
Detecon
Aer enabling this funcon, the device will detect the dredgers and trigger an alarm according to
the alarm sengs.
Steps
1.
Go to Conguraon → Ship Detecon → Scene Conguraon → Scene x → Rule .
2.
Select Ship Flow
Detecon from the drop-down list.
3.
Set the Overstaying Alarm Time. When the staying me of a ship is longer than the set value,
the ship is
idened as a dredger, and an alarm will be triggered.
4.
Set the min. size and max. size of the target. When the target is smaller or bigger than the set
sizes, the device can detect the target, but no alarm will be triggered.
5.
Oponal: Check Cancel Repeated Alarm. Alarms will not be repeatedly triggered when the ships
are in the same scene and at the same coordinates, and the size dierence of the ships is within
certain value.
6.
Click Draw Area. Click and drag the mouse in the live video window to draw the area. You can
drag the corners of the rectangle area to draw a polygon area.
7.
Oponal: Click Stop Drawing to nish drawing or click Clear All to clear all of the areas you set
without saving them.
8.
Click Save.
Thermal & Opcal Bi-spectrum PTZ Network Camera User Manual